| 24 MICROPHONES |
Number of Beams: Two patterns, either 5 or 6 beams
Polar Pattern: Custom
Frequency Response: 150Hz – 16kHz, +/- 3dB
Dynamic Range: 150Hz – 16kHz, > 70dB
|
| AMPLIFIER OUTPUT |
Uses P-Llink channels and C-Link channels based on configuration
Type: 5.08mm Black Header, Male, Phoenix type Euroblock
Audio: 2 channels
Output Power: 2x10W Max, 8Ω load*
Frequency Response: 20Hz – 22kHz @ +10dBu, +/ 0.5dB
THD + Noise: 20Hz – 22kHz @ +10dBu, 1W, < 0.2%
Dynamic Range: 20Hz – 22kHz @ +20dB, > 102dB, with 20kHz digital low pass filter
Crosstalk: Channel to Channel, stimulus at +20dBu receptor 10W output 8Ω load, 20Hz – 22kHz, < -60dB
|
| LED |
4 LED indicators on one end of unit:
Mute/Un-mute configuration with 8 color options, two blink patterns and warning indications
|
| CONFIGURATION |
Beam enable/disable
Acoustic Echo Cancellation (AEC) on/off
Noise Cancellation (NC) on/off
Filters:
– All Pass
– Low Pass
– High Pass
– Notch
– Notch
Automatic Level Control (ALC) on/off
Gain adjust
Mute on/off
Auto gate/Manual gate
|
| P-LINK PERIPHERAL BUS |
P-Link In & Out: Proprietary Network
Ports Type: RJ-45
Cable: RJ45 Cat5e, Cat6, Expandable
Distance: Up to 650 ft.
Daisy-Chain:
– Up to 3 Array units and additional P-Link compatible devices with each supported CONVERGE Pro 2 unit in the same chain
– Up to 6 array units in the same P-Link chain with 2 supported CONVERGE Pro 2 units connected through C-Link
Long Distance P-Link:
– Increases P-Link distance from 200 ft. to 650 ft.; (200M) max cable distance between any two units; Cat6, 550 MHz, 23 AWG, solid conductor cable;
– Do not use Copper Clad Aluminum (CCA) cable
|
| POWER SELECTION SWITCH |
Type: Slide Switch
Slide toward P-Link to power device by P-Link
Slide toward PoE to power device by PoE Injector
|
| CONFIGURATION & ADMINISTRATION SOFTWARE |
Pro CONSOLE® Software
|
| MOUNTING |
Ceiling mount (24” or 600mm drop-ceiling grid)
|
| POWER & THERMAL |
Power Type: PoE
Port Type: RJ-45
Power Source: PoE Injector or equivalent
PoE: IEEE 802.3at compliant devices providing 56V and 640 mA (36 W).
P-Link In – Mode B
PoE In – Mode A and Mode B
*BMA CT requires its own PoE (IEEE 802.3 at compliant) if 2x10W speakers are driven
Power Consumption:
– 100-240VAC, 50/60Hz
– 9.1 Watt typical without speaker amp
– 38W at max power 1kHz (2 x 10W)
– Thermal: 130 BTU/Hr at max power
– Operating Temperature: 14° F/-10° C to 104° F/40° C ambient temperature24” or 600mm drop-ceiling grid)
|
| DIMENSION & WEIGHT (WxHxD) |
24 IN REV 8.3 (and below):
– Product Dimension: 23.72 x 23.72 x 2.13 in (602.5 x 602.5 x 54.1 mm)
– Product Weight: 7.71 lbs (3.5 kg)
– Shipping Weight: 11.46 lbs (5.2 kg)
24 IN REV 8.4 (and above):
– Product Dimension: 23.72 x 23.72 x 2.13 in (602.5 x 602.5 x 54.1 mm)
– Product Weight: 11.1 lbs (5.0 kg)
– Shipping Weight: 14.2 lbs (6.4 kg)
600 mm:
– Product Dimension: 23.33 x 23.33 x 2.13 in (592.5 x 592.5 x 54.1 mm)
– Product Weight: 9 lbs (4.1 kg)
– Shipping Weight: 12.85 lbs (5.83 kg)
|
| SUPPORTED CONVERGE® PRO 2 |
910-3200-001 CONVERGE Pro 2 128
910-3200-001-D CONVERGE Pro 2 128D
910-3200-002 CONVERGE Pro 2 128T
910-3200-002-D CONVERGE Pro 2 128TD
910-3200-003 CONVERGE Pro 2 128V
910-3200-003-D CONVERGE Pro 2 128VD
910-3200-009-D CONVERGE Pro 2 128VTD
910-3200-005 CONVERGE Pro 2 48T
910-3200-006 CONVERGE Pro 2 48V
910-3200-008 CONVERGE Pro 2 48VT
910-3200-008-D CONVERGE Pro 2 48VTD
910-3200-008-D CONVERGE Pro 2 48VTD
|
| ACCCESSORIES |
910-3200-202 PoE Power supply kit for BMA CT
910-3200-204-50 50 ft RJ45 CAT6 Cable
910-3200-204-100 100 ft RJ45 CAT6 Cable
910-3200-204-150 150 ft RJ45 CAT6 Cable
910-3200-204-200 200 ft RJ45 CAT6 Cable
910-3200-205-AI Brackets, convert 600 to 625 mm
910-3200-205-CB BMA CT Conduit Box
|
| MOUNTS FOR NON-TILE CEILINGS |
910-3200-210 BMA Surface-Mount Kits 24in
910-3200-210-I BMA Surface-Mount Kits 600mm
910-3200-211 BMA Recessed-Mount Kits 24in
910-3200-211-I BMA Recessed-Mount Kits 600MM
|
| PART NUMBERS |
910-3200-205-U: 24in White BMA CT
910-3200-205-I: 600mm White BMA CT
|